170 research outputs found

    Management of COPD:Is there a role for quantitative imaging?

    Get PDF
    While the recent development of quantitative imaging methods have led to their increased use in the diagnosis and management of many chronic diseases, medical imaging still plays a limited role in the management of chronic obstructive pulmonary disease (COPD). In this review we highlight three pulmonary imaging modalities: computed tomography (CT), magnetic resonance imaging (MRI) and optical coherence tomography (OCT) imaging and the COPD biomarkers that may be helpful for managing COPD patients. We discussed the current role imaging plays in COPD management as well as the potential role quantitative imaging will play by identifying imaging phenotypes to enable more effective COPD management and improved outcomes

    Validation of a CT-guided intervention robot for biopsy and radiofrequency ablation: experimental study with an abdominal phantom

    Get PDF
    PURPOSE:We aimed to evaluate the accuracy of a needle-placement robot for biopsy and radiofrequency ablation on an abdominal phantom.METHODS:A master-slave robotic system has been developed that includes a needle-path planning system and a needle-inserting robot arm with computed tomography (CT) and CT fluoroscopy guidance. For evaluation of its accuracy in needle placement, a commercially available abdominal phantom (Model 057A; CIRS Inc.) was used. The liver part of the phantom contains multiple spherical simulated tumors of three different size spheres. Various needle insertion trials were performed in the transverse plane and caudocranial plane two nodule sizes (10 mm and 20 mm in diameter) to test the reliability of this robot. To assess accuracy, a CT scan was performed after each trial with the needle in situ.RESULTS:The overall error was 2 mm (0–2.6 mm), which was calculated as the distance from the planned trajectory before insertion to the actual needle trajectory after insertion. The standard deviations of the insertions on two nodules (10 mm and 20 mm in diameter) were 0.5 mm and 0.2 mm, respectively.CONCLUSION:The CT-compatible needle placement robot for biopsy and radiofrequency ablation shows relatively acceptable accuracy and could be used for radiofrequency ablation of nodules ≥10 mm under CT fluoroscopy guidance

    Pulmonary Metastases of Alveolar Soft-Part Sarcoma: CT Findings in Three Patients

    Get PDF
    Alveolar soft-part sarcoma is a rare soft tissue sarcoma of young adults with unknown histogenesis, and the organ most frequently involved in metastasis is the lung. We report the CT findings of three patients of pulmonary metastases of alveolar soft-part sarcoma, which manifested as clearly enhanced pulmonary nodules or masses. On enhanced scans, some of the masses were seen to contain dilated and tortuous intratumoral vessels

    The Effect of Calcipotriol on the Expression of Human β Defensin-2 and LL-37 in Cultured Human Keratinocytes

    Get PDF
    Background. Vitamin D has been reported to regulate innate immunity by controlling the expression of antimicrobial peptides (AMPs). Objective. We investigated the effect of calcipotriol on the expression of AMPs in human cultured keratinocytes. Methods. Keratinocytes were treated with lipopolysaccharide (LPS), TNF-α, Calcipotriol and irradiated with UVB, cultured, and harvested. To assess the expression of human beta defensin-2 and LL-37 in the control group, not exposed to any stimulants, the experimental group was treated with LPS, TNF-α, or UVB, and another group was treated again with calcipotriol; reverse transcriptase-polymerase chain reaction, Western blotting, and immunohistochemical staining were performed. Results. In the experimental group treated with LPS, UVB irradiation, and TNF-α, the expression of β-defensin and LL-37 was increased more than in the control group and then decreased in the experimental group treated with calcipotriol. Conclusions. Calcipotriol suppressed HBD-2 and LL-37, which were stimulated by UVB, LPS, and TNF-α

    Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway

    Get PDF
    parameters on the correct measurement of the airway dimension. Materials and Methods: An airway phantom with 11 poly-acryl tubes of various lumen diameters and wall thicknesses was scanned using a 16-MDCT (multidetector CT) at various tilt angles (0, 30, 45, and 60 ). The CT images were reconstructed at various reconstruction kernels and thicknesses. The axis of each airway was determined using the 3D thinning algorithm, with images perpendicular to the axis being reconstructed. The luminal radius and wall thickness was measured by the full-width-half-maximum method. The influence of the CT parameters (the size of the airways, obliquity on the radius and wall thickness) was assessed by comparing the actual dimension of each tube with the estimated values. Results: The 3D thinning algorithm correctly determined the axis of the oblique airway in all tubes (mean error: 0.91+-0.82 ). A sharper reconstruction kernel, thicker image thickness and larger tilt angle of the airway axis resulted in a significant decrease of the measured wall thickness and an increase of the measured luminal radius. Use of a standard kernel and a 0.75-mm slice thickness resulted in the most accurate measurement of airway dimension, which was independent of obliquity. Conclusion: The airway obliquity and imaging parameters have a strong influence on the accuracy of the airway wall measurement. For the accurate measurement of airway thickness, the CT images should be reconstructed with a standard kernel and a 0.75 mm slice thickness.This work was supported by the Korea Science and Engineering Foundation (KOSEF) grant funded by the Korea government (MOST) (No. R01-2006-000-11244-0)

    Direct experimental observation of the molecular Jeff=3/2 ground state in the lacunar spinel GaTa4Se8

    Full text link
    Strong spin-orbit coupling lifts the degeneracy of t2g orbitals in 5d transition-metal systems, leaving a Kramers doublet and quartet with effective angular momentum of Jeff = 1/2 and 3/2, respectively. These spin-orbit entangled states can host exotic quantum phases such as topological Mott state, unconventional superconductivity, and quantum spin liquid. The lacunar spinel GaTa4Se8 was theoretically predicted to form the molecular Jeff = 3/2 ground state. Experimental verification of its existence is an important first step to exploring the consequences of the Jeff = 3/2 state. Here, we report direct experimental evidence of the Jeff = 3/2 state in GaTa4Se8 by means of excitation spectra of resonant inelastic x-rays scattering at the Ta L3 and L2 edges. We found that the excitations involving the Jeff = 1/2 molecular orbital were suppressed only at the Ta L2 edge, manifesting the realization of the molecular Jeff = 3/2 ground state in GaTa4Se8.Comment: 25 pages, 5 figures + Supplementary Materials [10 pages, 5 figures

    Fasting glucose variability and risk of dementia in Parkinson’s disease: a 9-year longitudinal follow-up study of a nationwide cohort

    Get PDF
    BackgroundDiabetes is associated with an increased risk of Parkinson’s disease dementia (PDD); however, it is unknown whether this association is dependent on continuous hyperglycemia, hypoglycemic events, or glycemic variability. We aimed to investigate the relationship between visit-to-visit fasting glucose variability and PDD development in patients with Parkinson’s disease (PD).MethodsUsing data from the Korean National Health Insurance Service, we examined 9,264 patients aged ≥40 years with de novo Parkinson’s disease (PD) who underwent ≥3 health examinations and were followed up until December 2019. Glucose variability was measured using the coefficient of variation, variability independent of the mean, and average real variability. Fine and Gray competing regression analysis was performed to determine the effect of glucose variability on incident PDD.ResultsDuring the 9.5-year follow-up period, 1,757 of 9,264 (19.0%) patients developed PDD. Patients with a higher visit-to-visit glucose variability had a higher risk of future PDD. In the multivariable adjusted model, patients with PD in the highest quartile (subdistribution hazard ratio [SHR] = 1.50, 95% CI 1.19 to 1.88), quartile 3 (SHR = 1.29, 95% CI 1.02 to 1.62), and quartile 2 (SHR = 1.30, 95% CI 1.04 to 1.63) were independently associated with a higher risk of PDD than those in the lowest quartile.ConclusionWe highlighted the effect of long-term glucose variability on the development of PDD in patients with PD. Furthermore, our findings suggest that preventive measures for constant glucose control may be necessary to prevent PDD
    corecore